Large Scale Reactor Charging
- Large scale vessel charging glovebox from drums and other types of containers
- Drum interface with glovebox is via a host container to permit handling of differently sized drums without the need for changeover parts
- Material entry via Rapid Transfer Port, drum docking hoist or through opened front window
- Nitrogen purged working chambers with cascading pressure
- Twin Chamber design to protect the drum docking point from powder contamination
- Internal safe change inlet and outlet HEPA filters (Push-Push Filter Housings)
- Single, double or triple chamber systems
Small Scale Reactor Charging
- Small scale vessel charging glovebox, e.g. Seed Charging, small liquid editions, etc.
- Material entry via Rapid Transfer Port, Airlock (Passbox) or through opened front window
- Nitrogen purged working chamber
- Material transfer via funnel allows for clean down of the glovebox without draining into the process vessel
- Internal safe change inlet and outlet HEPA filters (change via Rapid Transfer Port, Continuous Liner Port or Airlock)
Large radius corners and edges for ease of cleaning